The Duet4 is an advanced auto-dialling digital communication device for adding GPRS, GSM, SMS and LAN reporting to control panels that have a telephone line connection.
Store price: 190,000€ Internet price(With V.A.T.): 186,504€
The Duet4 monitors the telephone line that is normally connected to the control panel’s PSTN connection. If a line fault is detected, the Duet4 sends a line fault alarm to the Alarm Receiving Centre on its radio or LAN path. Any subsequent alarm transmission from the control panel is then sent to the ARC via one of the Duet4 paths. In addition alarms can also be sent by SMS text to mobile phones. The Duet4 can be used as the primary or secondary path for alarm transmission but will be the main path for test calls. The Duet4 has 4 trigger inputs that can be activated independently. The Duet4 continuously monitors the radio path. If a radio path fault is detected, the Duet4 allows the control panel to dial out on the PSTN network and sends a radio fault alarm to the ARC on the LAN path (if available). The Duet4 D2660 can operate with control panels using DTMF Fast Format, Contact ID and SIA alarm reporting protocols, and can download to most panels via GSM. The Duet4 will require a GSM SIM card that is enabled for ‘GPRS, GSM data and SMS’ operation. The Duet4 is semi-housed in an ABS plastic case which protects the electronics and meets PSTN safety requirements. The Duet4 includes 4 outputs that can be controlled from the associated downloader or by sending SMS messages to the unit from a PC or mobile phone. Up/downloading telephone calls to the control panel via PSTN are unaffected by the Duet4.
Model
D2660 Duet4
Dimensions (h x w x d)
31mm x 142mm x 105 mm. Height with expander card fitted 55mm
Weight
150 grams. 180 grams with expander card
Telephone Path
Pass-through only, with premises telephone disconnect and line presence and incoming ring monitoring
LAN (Ethernet Path)
TCP/IP
Radio Path
GPRS/GSM and SMS, MMCX Connector, 50 Ohm
Power Requirements
9.6 volts to 15 volts DC, 0.5 volt maximum ripple
Current Consumption at 12V
60mA quiescent, 130mA peak without Expander
100mA quiescent, 200mA peak with Expander
Low Battery
10.8-11.0 volts fault, 11.8-12.0 volts restore
Inputs
Inputs 1 to 4: 5V logic, 30V tolerant, 250K pull-down at 5V
Outputs
FLT: Changeover relay (60V 1A contacts)
O/P 1 - 4: Open Collector pull-down, 100mA current limited, output high =< supply positive
Start +: 2K2 resistor pull-up to supply positive,
User Serviceable Parts
SIM card and NVM (NVM must be similar to part fitted at manufacture)
Security Grade
EN50136 Grade 1, 2 and 3
ATS Classification
EN50136 ATS classification 4
Parameters D2 M2 T3 S1 I2
Transmission Times
LAN (Ethernet) path, typically 5 seconds
Radio GSM path, typically 30 seconds
Environmental
EN50136 Environmental Class 1 and 2
Temperature
-20C to +60C transit, -10°C to +55°C operating
Humidity
0 - 80% non-condensing
Emissions
EN55022
Mounting
Any orientation
Warranty
2 years